Pureflow Bio

Pureflow Bio · Manufacturer in India

Ozone Destruct Units

Ozone destruct units treat residual ozone in off-gas from a designed ozone process. Pureflow Bio supplies off-gas treatment equipment from India for aquaculture and aquarium installations.

Made in IndiaOne-year warrantyDispatch within 15 working days
Ozone Destruct Units assembly and visible equipment arrangement
Equipment illustration. Confirm your supplied configuration in the quotation and approved drawing.

What are Ozone Destruct Units?

An ozone destruct unit treats ozone-bearing off-gas using the specified destruction medium and operating arrangement before the gas is discharged to its agreed destination.

Off-gas ozone destruction and dissolved-ozone residual control are separate duties.

Ozone Destruct Units applications

Ozonated RAS systems

Best for off-gas handling from a separately designed contact stage.

Aquarium life support

Best for coordinating gas treatment with ventilation and monitoring.

Hatchery treatment installations

Best for a defined gas duty with accessible servicing.

How Ozone Destruct Units work

Step 1

Collect the off-gas

Route the specified ozone-bearing gas from the contact system.

Step 2

Apply the selected destruction method

Pass gas through the medium or treatment arrangement stated in the supplied design.

Step 3

Verify the outlet

Monitor the agreed outlet and operating conditions before discharge through the planned route.

Ozone Destruct Units features and benefits

Dedicated gas treatment

Separates off-gas duty from the water-treatment equipment.

Duty-specific selection

Accounts for inlet ozone concentration and gas volume.

Moisture review

Helps establish condensate protection for the selected treatment method.

Service access

Allows inspection or replacement of the supplied medium and components.

Ozone Destruct Units models and specifications

Ozone Destruct Units model schedule

Ozone Destruct Units model schedule
ModelBody materialBody diameter (mm)Width (mm)Depth (mm)Maximum height (unit to confirm)Drain outlet (unit to confirm)Inlet (mm)Outlet (mm)Carbon media quantity (unit to confirm)Listed gas inlet concentration (unit to confirm)Listed gas outlet concentration (unit to confirm)Electrical supply listing (V)Enquiry
ODU-10Polypropylene (PP)3004754259902550632510,0.8230 / 440Enquire about ODU-10
ODU-30Polypropylene (PP)40067552512502563903510,0.8230 / 440Enquire about ODU-30
ODU-60Polypropylene (PP)500765610135050751105510,0.8230 / 440Enquire about ODU-60
ODU-100Polypropylene (PP)6008307201420509011010010,0.8230 / 440Enquire about ODU-100
ODU-200Polypropylene (PP)70092581015205011016019010,0.8230 / 440Enquire about ODU-200

The ODU model schedule lists PP bodies and the dimensions shown. The source does not give units for maximum height, drain size, carbon quantity or gas concentration, and prints the outlet concentration as “0,0.8”. Confirm these items, electrical phase, frequency, input power and the verified ozone-removal duty before ordering; the concentration figures are not a performance guarantee.

Configuration and supply details

Confirm materials, connection standard, dimensions, electrical requirements and included components for the selected equipment. The quotation defines current pricing and the approved scope.

Optional components

  • Destruction method and auxiliary equipment to model-specific quotation

Options are supplied only when included in the agreed quotation.

How to select Ozone Destruct Units

Off-gas ozone destruction and dissolved-ozone residual control are separate duties.

  • Maximum gas flow
  • Inlet ozone concentration
  • Temperature and humidity
  • Allowable pressure drop
  • Required outlet concentration and monitoring

Build your ozone destruct units enquiry brief

Record your design requirements for review. This tool does not calculate an unverified treatment capacity or automatically approve a model.

Ozone Destruct Units installation and maintenance

Installation and integration

Confirm condensate management, gas routing and allowable backpressure. Coordinate the unit with the contact chamber, ventilation and the supplied alarm strategy.

Routine maintenance

Follow the supplied medium or catalyst inspection schedule. Check condensate routes, seals and monitoring instruments before returning the unit to service.

Warranty, dispatch and installation

One-year equipment warranty

Confirm coverage and operating requirements in the quotation.

Dispatch within 15 working days

Dispatch follows order confirmation. Transport and site delivery time are additional.

Made in India

Manufactured by Pureflow Bio in Mysuru, Karnataka. Installation, commissioning and service across India are agreed for your project.

For complete turnkey projects, confirm the project schedule, utilities, site preparation, installation and commissioning responsibilities separately.

Request a Ozone Destruct Units quote

Share your application, preferred model and site requirements. Pureflow Bio will confirm the selected configuration and scope in your quotation.

    Fields marked * are required.






    Your enquiry is sent securely to our team so we can respond to your requirements. Please do not include passwords, payment details or other sensitive information.

    Ozone Destruct Units FAQs

    What does an ozone destruct unit do?

    It takes the leftover ozone gas vented from a skimmer or contact chamber and breaks it down into ordinary oxygen before it reaches the air. Without one, ozone builds up in the plant room and becomes a health hazard for staff.

    Do I really need one if my system is small?

    If any ozone gas leaves your skimmer or contact chamber, yes. Even small amounts irritate the lungs and eyes in a closed room, and you can stop noticing the smell after a few minutes. A destruct unit is cheap insurance.

    How does it work?

    Our units pass the off-gas through activated carbon in a PP body. The carbon reacts with the ozone and converts it to oxygen. The carbon is used up slowly over time and needs topping up or replacing.

    How often does the carbon need changing?

    It depends on how much ozone reaches the unit and how humid the gas is. Wet off-gas wears carbon out faster. Check it regularly with an ozone test at the outlet and replace the carbon when ozone starts to come through.

    How do I size an ozone destruct unit?

    We size it by the maximum gas flow coming off your skimmer or chamber, the ozone concentration in that gas and how humid it is. Send us the generator output and how the ozone is being dissolved, and we'll recommend a model.

    Plan your complete aquaculture or aquarium system

    Connect ozone destruct units to the wider treatment process

    Discuss equipment integration, utilities and a coordinated project scope with Pureflow Bio.

    Scroll to Top