Pureflow Bio · Manufacturer in India
Ozone Contact Chambers
Ozone contact chambers bring ozone gas and water together in a defined treatment loop. Pureflow Bio manufactures contact-chamber and skid arrangements in India for engineered aquatic treatment projects.

What are Ozone Contact Chambers?
An ozone contact chamber provides a defined gas-and-water mixing stage within an ozone treatment system, with transfer and contact conditions established for the application.
Ozone Contact Chambers applications
RAS facilities
Best for a dedicated ozone treatment branch with controlled return water.
Public aquariums and oceanariums
Best for an engineered contact stage with livestock protection measures.
Aquaculture water treatment
Best for a defined oxidation objective and commissioning protocol.
How Ozone Contact Chambers work
Introduce the treatment stream
Feed water and ozone through the approved injection arrangement.
Provide contact conditions
Operate the selected vessel and mixing route at the design flow and pressure.
Separate and verify
Manage off-gas and confirm the permitted return-water residuals before the stream rejoins the system.
Ozone Contact Chambers features and benefits
Defined contact vessel
Creates a planned location for the gas-water treatment stage.
Integrated pipework
Coordinates injection, circulation and isolation in the agreed arrangement.
Accessible instrumentation
Allows the specified pressure and residual measurements to be incorporated.
Separable off-gas route
Provides a connection for the designed gas-handling equipment.
Ozone Contact Chambers models and specifications
Ozone Contact Chambers model schedule
| Model | Tank diameter (mm) | Ozone dosing (g/h) | Inlet (mm × quantity) | Outlet (mm × quantity) | Tank height (unit to confirm) | Mixing system | Working pressure (bar) | Power listing (unit to confirm) | Enquiry |
|---|---|---|---|---|---|---|---|---|---|
| OCSU 10-20 | 740 | 10–20 | 50 × 1 | 50 × 1 | 1450 | Static mixer and venturi injector | 2–7 | 2.4 | Enquire about OCSU 10-20 |
| OCSU 20-35 | 850 | 20–30 | 63 × 1 | 63 × 1 | 1495 | Static mixer and venturi injector | 2–7 | 3.7 | Enquire about OCSU 20-35 |
| OCSU 50-75 | 1100 | 50–75 | 110 × 1 | 90 × 1 | 1600 | Static mixer and venturi injector | 2–7 | 5.8 | Enquire about OCSU 50-75 |
| OCSU 110-125 | 1400 | 100–125 | 110 × 1 | 110 × 1 | 1700 | Static mixer and venturi injector | 2–7 | 6.9 | Enquire about OCSU 110-125 |
| OCSU 150-175 | 1600 | 150–175 | 160 × 1 | 160 × 1 | 2100 | Static mixer and venturi injector | 2–7 | 7.10 | Enquire about OCSU 150-175 |
| OCSU 200-250 | 1950 | 200–250 | 200 × 1 | 200 × 1 | 2150 | Static mixer and venturi injector | 2–7 | 12.15 | Enquire about OCSU 200-250 |
The OCSU schedule specifies ozone dosing, tank diameter, connections and a 2–7 bar working-pressure listing. Tank-height and power units are not printed. Model names OCSU 20-35 and OCSU 110-125 differ from their dosing rows of 20–30 and 100–125 g/h; confirm the selected model, pressure documentation, power units and electrical supply in the quotation. These listings do not establish a water flow or contact-time guarantee.
Configuration and supply details
Confirm materials, connection standard, dimensions, electrical requirements and included components for the selected equipment. The quotation defines the approved scope.
Optional components
- Injection, pumps and controls as expressly listed in the quotation
Options are supplied only when included in the agreed quotation.
Engineering & procurement
Contact time, residual control and material compatibility
A contact chamber must work within a complete ozone process. Vessel dimensions and a generator connection do not establish a verified contact time or suitable return-water condition.
Use effective contact volume
Nominal hydraulic time = working contact volume ÷ water flow, using consistent units. Short-circuiting, gas hold-up and mixing can make actual exposure differ from nominal residence time. Confirm the selected operating level and hydraulic arrangement.
Treat marine oxidant residuals as a design issue
Marine and brackish water chemistry can generate secondary oxidants. Define monitoring, residual-removal arrangements and acceptance limits for the actual water and species. Do not rely on an assumed universal ORP setting.
| Selection item | Specify or verify | Why it changes the selection |
|---|---|---|
| Contact arrangement | Working volume, flow distribution, mixing and nominal contact time | Outside vessel dimensions do not establish the effective treatment volume. |
| Dosing and transfer | Ozone mass, injected gas flow and transfer basis | Generator output and dissolved dose are not interchangeable. |
| Pressure and materials | Approved pressure, pressure protection, seals and gas/water compatibility | The project drawing and component ratings govern installation. |
| Residual and off-gas handling | Water residual control, gas destruct, ventilation and interlocks | Water and gas streams need their own defined treatment routes. |
How to select Ozone Contact Chambers
A chamber volume does not establish treatment performance unless the actual flow, mixing and ozone chemistry have been reviewed.
- Water flow and ozone demand
- Effective contact volume
- Operating pressure and gas transfer
- Residual monitoring and off-gas flow
- Materials, return-water limits and ventilation
Build your ozone contact chambers enquiry brief
Record your design requirements for review. This tool does not calculate an unverified treatment capacity or automatically approve a model.
Ozone Contact Chambers installation and maintenance
Installation and integration
Confirm the pressure design, bypass and isolation arrangements with the approved drawing. Provide the specified off-gas treatment, drainage and monitoring before commissioning.
Routine maintenance
Inspect seals, injection components, drains and monitoring points. Follow the agreed shutdown procedure before opening the contact vessel.
Warranty, dispatch and installation
One-year equipment warranty
Confirm coverage and operating requirements in the quotation.
Dispatch within 15 working days
Dispatch follows order confirmation. Transport and site delivery time are additional.
Made in India
Manufactured by Pureflow Bio in India. Installation, commissioning and service across India are agreed for your project.
For complete turnkey projects, confirm the project schedule, utilities, site preparation, installation and commissioning responsibilities separately.
Request an ozone contact chamber quote
Share your application, preferred model and site requirements. Pureflow Bio will confirm the selected configuration and scope in your quotation.
Ozone Contact Chambers FAQs
What is an ozone contact chamber for?
It gives ozone time to dissolve and react with the water away from your fish. Ozone gas is mixed into a side stream, given enough contact time to oxidise organics and kill microbes, and the water is then sent on for residual removal before it returns to the system.
Why not just add ozone straight into the tank?
Ozone is toxic to fish at very low levels and burns gills. A contact chamber keeps the reaction in a closed vessel and lets you control the dose, so the fish only ever see clean, ozone-free water.
How is the contact chamber sized?
By the flow you want to treat, how much ozone you're adding and the contact time needed. Our OCSU models are specified by ozone dose, tank diameter, connections and a 2 to 7 bar working pressure. We help pick the model once we know your feed rate and treatment goal.
What happens to the ozone that doesn't dissolve?
It leaves the chamber as off-gas and must go through an ozone destruct unit before it's vented. Residual ozone still in the water is removed by contact time, carbon, a trickle filter or UV before the water returns to the fish.
What materials can handle ozone?
Ozone attacks many plastics and rubbers. Contact chambers and the fittings around them need ozone-resistant materials and seals, which is why it pays to buy the chamber and its fittings as a matched set rather than improvising with standard pipe fittings.
Plan your complete aquaculture or aquarium system
Connect ozone contact chambers to the wider treatment process
Discuss equipment integration, utilities and a coordinated project scope with Pureflow Bio.




