MAT-KULING decided to design ozone generators contact towers from scratch. Our equipment derived after spending over 3 years in R&D and field trials. Traditionally it was considered that providing a standard pressurized chamber for the ozone to be infused in water was enough. MAT-KULING has the field expertise from operating large ozone generators in saline and fresh water farm systems and understands that there are multiple details that need to be addressed in order to secure the brood-stock of the fish farm. Details in the design and safe operation of the device are unique on MAT-KULING ozone contact chambers.
Ozone is a gas that needs to be infused into water under a compressed infusion process, in multiple points of a filtration system. In saline water, protein fractionators (skimmers) are traditionally used to achieve this through a venturi device, infusing ozone mixed with air into the water column.
Latest developments have shown us that the infusion of ozone is not best achieved only by using this venturi infusion. Thus, a pressurized vessel needs to be implemented to infuse ozone into the fresh water column under a pressurized mixture. Moreover, In fresh water filtration systems, protein fractionation is not so common. Therefore the ozone contact tower is a mandatory component of a RAS farm.
Our engineering department is in position to assist our clients in selecting the proper equipment. We have the expertise to train your technical staff how to use ozone safely. The Ozone Contact Chambers are suitable for any fresh and saline water aquaculture application. All components used on our Ozone Contact Towers are tested for ozone oxidation and saline vapors corrosion. Contact MAT today to find out how Ozone can alter the production yield of your fish farm.
wdt_ID | OZONATION SKID FOR MARINE/ FRESH WATER | OCS-10 | OCS-20 | OCS-50 | OCS-100 | OCS-150 | OCS-250 |
---|---|---|---|---|---|---|---|
28 | Footprint Depth [mm] | 1150 | 1300 | 1430 | 1800 | 2020 | 2465 |
29 | Footprint Width [mm] | 1850 | 1860 | 2760 | 4745 | 5175 | 5925 |
30 | Max. Height [mm] | 2600 | 2600 | 2850 | 2900 | 3500 | 3385 |
31 | Contact Tank Diameter [mm] | 600 | 800 | 1200 | 1600 | 1800 | 2200 |
32 | Installed Power [kW] | 5.5 | 5.5 | 5.5 | 11 | 11 | 18.5 |
33 | Basic Unit Total Electric Consumption [kWh] | 2.7 | 3.2 | 4.6 | 8.5 | 7.4 | 18 |
34 | Supply Voltage (50Hz) [V] | 3~400/230 | 3~400/230 | 3~400/230 | 3~400 | 3~400 | 3~400 |
35 | Inlet Size [mm] | 50 | 63 | 110 | 140 | 160 | 200 |
36 | Outlet Size [mm] | 40 | 50 | 90 | 140 | 160 | 200 |
37 | Contact Time [min] | 5 | 5 | 5 | 5 | 5 | 5 |
38 | Ozone Concentration [ppm] | 0,5-2 | 0,5-2 | 0,5-2 | 0,5-2 | 0,5-2 | 0,5-2 |
39 | Ozone Dosing [g/h] | 10 | 20 | 50 | 100 | 150 | 250 |
40 | Ozone Dosing [L/min] | 4,5 | 5 | 10 | 39 | 49 | 40 |
41 | CT Value | 10 | 10 | 10 | 10 | 10 | 10 |
42 | Booster Pump Material | PP | PP | PP | PP | PP | PP |
43 | Pressure Sensor TANK-IN | YES | YES | YES | YES | YES | YES |
44 | Pump Model | TMR 30.25 | TMR 30.25 | TMR 20.36 | CMO-N 65-160 | CMO-N 65-160 | CDI-QL 125-100-250 |
45 | Pump Variable Frequency Driver Model | EP66-0055 T3 | EP66-0055 T3 | EP66-0055 T3 | EP66-0110 T3 | EP66-0150 T3 | EP66-0220 T3 |
46 | Ozone Contact Tank Model/ Cylinder height | R60C/1700 | R80C/1700 | R120C/1700 | R160C/1700 | R180C/2000 | R220C/2000 |
47 | Ozone Contact Tank Total Height [mm] | 2270 | 2350 | 2550 | 2750 | 3150 | 3350 |
48 | Dry Weight (kg) | 180 | 250 | 460 | 1250 | 1420 | 1875 |
49 | Ozone Destruct | STANDARD | STANDARD | STANDARD | STANDARD | STANDARD | STANDARD |
50 | Max Line Pressure [bar] | 1,7 | 1,9 | 1,7 | 1,7 | 1,7 | 1,7 |
51 | Pump Flow Rate [m³/h] | 5 | 10 | 25 | 50 | 75 | 125 |
52 | Venturi Inlet Pressure [bar] | 3 | 3 | 3 | 3 | 3 | 3 |
53 | Tank Operating Pressure [bar] | 1,9 | 2,1 | 1,9 | 1,9 | 1,9 | 1,9 |
54 | Ozone GAS Suction Rate [L/min] | 4,5 | 5 | 10 | 39 | 49 | 40 |
OZONATION SKID FOR MARINE/ FRESH WATER | OCS-10 | OCS-20 | OCS-50 | OCS-100 | OCS-150 | OCS-250 |
wdt_ID | OZONATION SKID FOR MARINE/ FRESH WATER OPTIONAL FEATURES | OCS-10 | OCS-20 | OCS-50 | OCS-100 | OCS-150 | OCS-250 |
---|---|---|---|---|---|---|---|
55 | Pressure Probe TANK-OUT | optional | optional | optional | optional | optional | optional |
56 | PH/ORP Probe & Fittings | optional | optional | optional | optional | optional | optional |
57 | DO3 PROBE & Fitting | optional | optional | optional | optional | optional | optional |
58 | Control Board | optional | optional | optional | optional | optional | optional |
59 | Control Board with PLC | optional | optional | optional | optional | optional | optional |
60 | Ambient Ozone Monitor | optional | optional | optional | optional | optional | optional |
61 | FRP Body Ozone Contact Tank | optional | optional | optional | optional | optional | optional |
62 | Ozone Contact Skid Pump | optional | optional | optional | optional | optional | optional |
63 | Ozone Contact Skid Pump VFD | optional | optional | optional | optional | optional | optional |
64 | Ozone Dosing Skid Digital Flowmeter | optional | optional | optional | optional | optional | optional |
65 | Automatic Air Purge 1” | optional | optional | optional | optional | optional | optional |
66 | Automatic Air Purge 2” | optional | optional | optional | optional | optional | optional |
67 | Pressure Relief Valve | optional | optional | optional | optional | optional | optional |
OZONATION SKID FOR MARINE/ FRESH WATER OPTIONAL FEATURES | OCS-10 | OCS-20 | OCS-50 | OCS-100 | OCS-150 | OCS-250 |
wdt_ID | OCT TANKS | DESCRIPTION | MATERIAL | TYPE | DIAMETER/ FOOTPRINT SIZE MM | HEIGHT MM | TANK VOLUME M3 | NOMINAL OPERATIONAL PRESSURE BAR | MAXIMUM PERMITTED PRESSURE BAR |
---|---|---|---|---|---|---|---|---|---|
68 | OC T-10 | OZONE CONTACT TANK | FRP | Vertical | 1700 | 2270 | 0,45 | 2.5 | 6 |
69 | OC T-20 | OZONE CONTACT TANK | FRP | Vertical | 1700 | 2350 | 0,85 | 2.5 | 6 |
70 | OC T-50 | OZONE CONTACT TANK | FRP | Vertical | 1700 | 2550 | 2,5 | 2.5 | 6 |
71 | OCT-100 | OZONE CONTACT TANK | FRP | Vertical | 1700 | 2750 | 4,5 | 2.5 | 6 |
72 | OCT-150 | OZONE CONTACT TANK | FRP | Vertical | 2000 | 3150 | 6,5 | 2.5 | 6 |
73 | OCT-250 | OZONE CONTACT TANK | FRP | Vertical | 2000 | 3350 | 11 | 2.5 | 6 |
74 | OCT-500 | OZONE CONTACT TANK | FRP | Vertical | TBD | TBD | TBD | 2.5 | 6 |
75 | OCT-1000 | OZONE CONTACT TANK | FRP | Vertical | TBD | TBD | TBD | 2.5 | 6 |
OCT TANKS | DESCRIPTION | MATERIAL | TYPE | DIAMETER/ FOOTPRINT SIZE MM | HEIGHT MM | TANK VOLUME M3 | NOMINAL OPERATIONAL PRESSURE BAR | MAXIMUM PERMITTED PRESSURE BAR |
wdt_ID | OZONE DOSING SKID FOR MARINE/ FRESH WATER | ODS-10 | ODS-20 | ODS-50 | ODS-100 | ODS-250 | ODS-500 | ODS-1000 |
---|---|---|---|---|---|---|---|---|
76 | Footprint Depth [mm] | 700 | 700 | 700 | 700 | 700 | 700 | 800 |
77 | Footprint Width [mm] | 1135 | 1135 | 1140 | 1270 | 1270 | 1750 | 1900 |
78 | Max. Height [mm] | 2130 | 2130 | 2130 | 2180 | 2230 | 2500 | 2500 |
79 | Installed Power [kW] | 1,1 | 1,1 | 1,3 | 2,2 | 2,2 | 3,7 | 4,8 |
80 | Supply Voltage (50Hz) [V] | 3~400/230 | 3~400/230 | 3~400/230 | 3~400/230 | 3~400/230 | 3~400/230 | 3~400 |
81 | Inlet Size [mm] | 50 | 50 | 50 | 63 | 63 | 90 | 110 |
82 | Outlet Size [mm] | 50 | 50 | 50 | 63 | 63 | 90 | 110 |
83 | Ozone Dosing [g/h] | 10 | 20 | 50 | 100 | 250 | 500 | 1000 |
84 | Ozone Dosing [L/min] | 4,5 | 6 | 10 | 39 | 40 | 80 | 160 |
85 | Pump Model pump | 21-40/53 H | 21-40/53 H | 21-40/54 H | 21-40/58 G | 21-40/58 G | 21-60/46 G | 21-80/34 G |
86 | Max Outlet Pressure (Higher pressures possible with custom design) [bar] | 0,7 | 0,7 | 0,7 | 0,7 | 0,7 | 0,7 | 0,7 |
87 | Inlet/outlet pressure monitors gauge/bar | 1–4 | 1–4 | 1–4 | 1–4 | 1–4 | 1–4 | 1–4 |
88 | Pump Flow Rate @ Max line pressure [m³/h] | 7,3 | 7,3 | 7,7 | 14 | 14 | 40 | 63 |
89 | Ozone GAS Suction Rate @ Max line pressure [L/min] | 5 | 6 | 10 | 39 | 40 | 80 | 160 |
90 | Venturi Model vnt | 250M | 260M | 260M | 350M | 350M | 430M | 600M |
OZONE DOSING SKID FOR MARINE/ FRESH WATER | ODS-10 | ODS-20 | ODS-50 | ODS-100 | ODS-250 | ODS-500 | ODS-1000 |
wdt_ID | OZONE DOSING SKID FOR MARINE/ FRESH WATER OPTIONAL FEATURES | ODS-10 | ODS-20 | ODS-50 | ODS-100 | ODS-250 | ODS-500 | ODS-1000 |
---|---|---|---|---|---|---|---|---|
91 | Variable Frequancy Driver vfd | EP66-0015 T3 | EP66-0015 T3 | EP66-0015 T3 | EP66-0022 T3 | EP66-0022 T3 | EP66-0040 T3 | EP66-0055 T3 |
92 | ORP/PH Probe & Probe Fitting | optional | optional | optional | optional | optional | optional | optional |
93 | DO3 Probe & Probe Fitting | optional | optional | optional | optional | optional | optional | optional |
94 | Control Board | optional | optional | optional | optional | optional | optional | optional |
95 | Digital pressure probes | optional | optional | optional | optional | optional | optional | optional |
96 | PLC Control | optional | optional | optional | optional | optional | optional | optional |
97 | Ozone Ambient Detector | optional | optional | optional | optional | optional | optional | optional |
98 | ODS Booster Pump | optional | optional | optional | optional | optional | optional | optional |
99 | Digital Flowmeter | optional | optional | optional | optional | optional | optional | optional |
OZONE DOSING SKID FOR MARINE/ FRESH WATER OPTIONAL FEATURES | ODS-10 | ODS-20 | ODS-50 | ODS-100 | ODS-250 | ODS-500 | ODS-1000 |
* MAT-KULING AS™ preserves the right to update anytime the listed prices (if any). Every effort has been made so that the above specs are accurate. However please contact our Sales Department for up to date technical data, electrical specs according to your regional requirements and current Ex-Works pricelist. The listed prices are for the basic equipment and do not include any optional components.